Titolo

IEG-TC1

Electromagnetic level indicators to one or two contacts
1" Bsp threaded Connection
SPST or SPDT Contacts

Material
brass
Output
on/off
Threaded connections
Threaded - 1"GAS

USE:
Made to ensure, with maximum safety, the minimum or maximum level of liquids in tanks.
Suitable for tanks containing liquids compatible with the brass tube, such as hydraulic and lubricant oils (with density not higher than 80°E), petroleum, etc.

OPERATION:
When the float of the indicator encounters the Reed switch at the pre-established point, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or activating or disconnecting any electrical equipment connected to it.

FITTING:
The indicator must be fitted in the vertical position, and the float must be at least 35mm from ferrous surfaces (walls, tanks, etc.).

NB:
The IEG - TCMM level indicator with SPDT (exchange) separate contacts or with one common, requires an aluminium connection head containing an adequate number of terminals for the use (5 or 6).